How to solve S18 error?
S18: Multi-turn Encoder Error
Product: xArm series, UF 850, Lite6
UFactory version: V2.4.0+
Please note that if the arm is not used for a long time(≥3 months), you need to power on the arm for 6 hours every 3 months to charge the built-in battery of the arm, otherwise the encoder data may be lost and report S18 error.
Clear Error:
Enter 'Settings-General-Debugging Tools-Joint', click 'clear Multi-turn Error', then power off the control box.
Powe on the control box and see if the problem is solved.